ASCO 300 Series Automatic Transfer...

$1,748.00

The ASCO 300 Series ATS is perfect for applications where power interruptions are not an option. The 300 series switch has proven its dependability in critical industries such as telecom, agriculture, municipal and medical. The equipment is listed to UL standard 1008 to comply with safety and NEC installation requirements. The ASCO 300 Series switches are also the most compact designs for automatic power transfer switches in the industry.

 

Price Includes Freight to a Business Address – The customer is responsible for unloading merchandise upon delivery.

 

Printable Brochure:

ASCO 300 Series

 

Available on backorder

Asco 300 Series ATS – 1 PH – 2 Pole

Asco 300 Series ATS – 3 Phase – 3 Pole

Asco 300 Series ATS – 3 Phase – 4 Pole

Transfer Switch Enclosure *

NEMA 1 enclosure is standard. NEMA 3R enclosure provides protection against falling rain, sleet, snow, and external ice formation. Indoors they protect against dripping water.

Deluxe Engine Exerciser

Programmable engine exerciser that provides for weekly or biweekly operation (part #11BE)

Strip Heater Wired Externally

Strip Heater with thermostat for extremely cold areas to prevent condensation and freezing of this condensation. External 120 volt power source required. (part #44a)

Strip Heater Wired To Load Terminals

Strip Heater with thermostat, wired to load terminals: 208-240, 360-380, 460-480, 550-600 volts. Contains wiring harnesses for all transfer switch sizes. (part # 44g)

Compare

Description

ASCO 300 Series Automatic Transfer Switch

The ASCO 300 Series ATS is perfect for applications where power interruptions are not an option. The 300 series switch has proven its dependability in critical industries such as telecom, agriculture, municipal and medical. The equipment is listed to UL standard 1008 to comply with safety and NEC installation requirements. The ASCO 300 Series switches are also the most compact designs for automatic power transfer switches in the industry. The following features set these switches apart.

Electrical Features

  • 600 volt spacing per UL and CSA standards.
  • Interfacing relays are industrial grade, plug-in type with dust covers.
  • Meets or exceeds the requirements for Electromagnetic Compatibility (EMC).
  • ANSI C37.90A/IEEE472 Voltage Surge Test
  • NEMA ICS-109.21 Impulse Withstand Test
  • Digital circuitry isolated from line voltages
  • IEC 801-2: Electrostatic discharge (ESD) immunity
  • ENV50140 and IEC 803-1: Radiated electromagnetic field immunity
  • IEC 801-4: Electrical fast transient (EFT) immunity
  • ENV50142: Surge transient immunity
  • ENV50141: Conducted radio-frequency field immunity
  • EN55011: Group 1, Class A conducted and radiated emissions
  • Optically isolated RS-485 Serial Port
  • EN61000- 4-11 voltage dips and interruptions immunity.

Standard Selectable Features

  • Inphase monitor to transfer motor loads, without any intentional off time to prevent motor inrush currents from exceeding normal starting levels.
  • Engine exerciser to automatically test backup generator each week. Includes control switch for testing with or without load.
  • Selective load disconnect, double-throw contact to operate at an adjustable 0 to 20 second time delay prior to transfer and reset 0 to 20 seconds after
  • 60 Hz or 50 Hz selector switch.
  • Three-phase/single-phase selector switch.

Voltage & Frequency Sensing 

  • Adjustable three-phase, close differential voltage sensing on normal source.
  • Normal source pickup voltage is adjustable to 95% of nominal; drop-out is adjustable from 70 to 90% of nominal.
  • Frequency sensing on emergency source. Pickup at 95% and dropout at 85% of nominal.

Time Delays:

  • Adjustable time delay to override momentary normal source outages to delay all transfer switch and engine-starting signals.
  • Transfer to emergency time delay. Adjustable from 0 to 5 minutes for controlled timing of load transfer to emergency.
  • Retransfer to normal time delay. Adjustable to 30 minutes.
  • Five-minute unloaded running time delay for emergency engine generator cool down.
  • Four-second time delay to override momentary to ignore momentary voltage and frequency transients during initial genset loading.

Type 1  Indoor Enclosure:

  • Listed to UL 50 standard for electrical equipment enclosures.
  • Fabricated from 14 gauge steel.
  • Finish - textured RAL 7035 light gray polyester powder coating
  • Doors secured with captive fasteners.
  • Conduit knockouts on bottom, and both sides.

Type 3R Outdoor Secure Enclosure:

  • Door over door secure construction.
  • Listed to UL 50 standard for electrical equipment enclosures.
  • Fabricated from heavy gauge aluminum alloy suited to the size and ampere rating of the switch.
  • Highly corrosion resistant
  • Finish - textured RAL 7035 light gray polyester powder coating.
  • Doors secured with captive fasteners.
  • Gasketed enclosure minimizes ingress of water and dust.
  • Internal dead front panel for user safety when accessing controls.
  • Conduit knockouts on bottom, and both sides.

Poles:

  • 70 -1,000 Amp 1-PH - 2 Pole
  • 70 -1,000 Amp 3-PH - 3 Pole
  • 70 -1,000 Amp 3-PH - 4 Pole

Actual Dimensions (Inches) (W x H x D):

  • 70 Amp in NEMA 1 Enclosure - 17.5 x 31 x 11.75
  • 104 Amp in NEMA 1 Enclosure - 17.5 x 31 x 11.75
  • 150 Amp in NEMA 1 Enclosure - 17.5 x 31 x 11.75
  • 200 Amp in NEMA 1 Enclosure - 17.5 x 31 x 11.75
  • 230 Amp in NEMA 1 Enclosure - 18 x 48 x 13
  • 260 Amp in NEMA 1 Enclosure - 18 x 48 x 13
  • 400 Amp in NEMA 1 Enclosure - 18 x 48 x 13
  • 600 Amp in NEMA 1 Enclosure - 24 x 63 x 17
  • 800 Amp in NEMA 1 Enclosure - 34 x 72 x 20
  • 1000 Amp in NEMA 1 Enclosure - 34 x 72 x 20
  • 70 Amp in NEMA 3R Enclosure - 17.5 x 35 x 11.75
  • 104 Amp in NEMA 3R Enclosure - 17.5 x 35 x 11.75
  • 150 Amp in NEMA 3R Enclosure - 17.5 x 35 x 11.75
  • 200 Amp in NEMA 3R Enclosure - 17.5 x 35 x 11.75
  • 230 Amp in NEMA 3R Enclosure - 18 x 50.5 x 14.5
  • 260 Amp in NEMA 3R Enclosure - 18 x 50.5 x 14.5
  • 400 Amp in NEMA 3R Enclosure - 18 x 50.5 x 14.5
  • 600 Amp in NEMA 3R Enclosure - 24 x 63 x 18.5
  • 800 Amp in NEMA 3R Enclosure - 34 x 75 x 20
  • 1000 Amp in NEMA 3R Enclosure - 34 x 75 x 20

Actual Weight (Pounds):

  • 70 Amp in NEMA 1 Enclosure - 73 Lbs
  • 104 Amp in NEMA 1 Enclosure - 73 Lbs
  • 150 Amp in NEMA 1 Enclosure - 73 Lbs
  • 200 Amp in NEMA 1 Enclosure - 73 Lbs
  • 230 Amp in NEMA 1 Enclosure - 110 Lbs
  • 260 Amp in NEMA 1 Enclosure - 110 Lbs
  • 400 Amp in NEMA 1 Enclosure - 110 Lbs
  • 600 Amp in NEMA 1 Enclosure - 270 Lbs
  • 800 Amp in NEMA 1 Enclosure - 475 Lbs
  • 1000 Amp in NEMA 1 Enclosure - 475 Lbs
  • 70 Amp in NEMA 3R Enclosure - 87 Lbs
  • 104 Amp in NEMA 3R Enclosure - 87 Lbs
  • 150 Amp in NEMA 3R Enclosure - 87 Lbs
  • 200 Amp in NEMA 3R Enclosure - 87 Lbs
  • 230 Amp in NEMA 3R Enclosure - 140 Lbs
  • 260 Amp in NEMA 3R Enclosure - 140 Lbs
  • 400 Amp in NEMA 3R Enclosure - 140 Lbs
  • 600 Amp in NEMA 3R Enclosure - 672 Lbs
  • 800 Amp in NEMA 3R Enclosure - 672 Lbs
  • 1000 Amp in NEMA 3R Enclosure - 672 Lbs

Shipping Dimensions (Inches) (W x H x D):

  • 70 Amp in NEMA 1 Enclosure - 25 x 38 x 20
  • 104 Amp in NEMA 1 Enclosure - 25 x 38 x 20
  • 150 Amp in NEMA 1 Enclosure - 25 x 38 x 20
  • 200 Amp in NEMA 1 Enclosure - 25 x 38 x 20
  • 230 Amp in NEMA 1 Enclosure - 25 x 55 x 20
  • 260 Amp in NEMA 1 Enclosure - 25 x 55 x 20
  • 400 Amp in NEMA 1 Enclosure - 25 x 55 x 20
  • 600 Amp in NEMA 1 Enclosure - 31 x 70 x 24
  • 800 Amp in NEMA 1 Enclosure - 41 x 79 x 27
  • 1000 Amp in NEMA 1 Enclosure - 41 x 79 x 27
  • 70 Amp in NEMA 3R Enclosure - 25 x 42 x 19
  • 104 Amp in NEMA 3R Enclosure - 25 x 42 x 19
  • 150 Amp in NEMA 3R Enclosure - 25 x 42 x 19
  • 200 Amp in NEMA 3R Enclosure - 25 x 42 x 19
  • 230 Amp in NEMA 3R Enclosure - 25 x 58 x 21
  • 260 Amp in NEMA 3R Enclosure - 25 x 58 x 21
  • 400 Amp in NEMA 3R Enclosure - 25 x 58 x 21
  • 600 Amp in NEMA 3R Enclosure - 31 x 70 x 25
  • 800 Amp in NEMA 3R Enclosure - 41 x 79 x 27
  • 1000 Amp in NEMA 3R Enclosure - 41 x 79 x 27

Shipping Weight (Pounds):

  • 70 Amp in NEMA 1 Enclosure - 75 Lbs
  • 104 Amp in NEMA 1 Enclosure - 75 Lbs
  • 150 Amp in NEMA 1 Enclosure - 75 Lbs
  • 200 Amp in NEMA 1 Enclosure - 75 Lbs
  • 230 Amp in NEMA 1 Enclosure - 125 Lbs
  • 260 Amp in NEMA 1 Enclosure - 125 Lbs
  • 400 Amp in NEMA 1 Enclosure - 125 Lbs
  • 600 Amp in NEMA 1 Enclosure - 324 Lbs
  • 800 Amp in NEMA 1 Enclosure - 460 Lbs
  • 1000 Amp in NEMA 1 Enclosure - 460 Lbs
  • 70 Amp in NEMA 3R Enclosure - 87 Lbs
  • 104 Amp in NEMA 3R Enclosure - 87 Lbs
  • 150 Amp in NEMA 3R Enclosure - 87 Lbs
  • 200 Amp in NEMA 3R Enclosure - 87 Lbs
  • 230 Amp in NEMA 3R Enclosure - 140 Lbs
  • 260 Amp in NEMA 3R Enclosure - 140 Lbs
  • 400 Amp in NEMA 3R Enclosure - 140 Lbs
  • 600 Amp in NEMA 3R Enclosure - 328 Lbs
  • 800 Amp in NEMA 3R Enclosure - 543 Lbs
  • 1000 Amp in NEMA 3R Enclosure - 543 Lbs

Optional Accessories  

Accessory 11BG - A programmable engine exerciser that provides for weekly or biweekly operation, includes one form C contact for source availability of normal and emergency (contact rating 2 amps @ 30VDC, 0.5 amp. @ 125 VAC resistive). The programmable engine exerciser incorporates a 7 day or 14 day time base with a digital readout display. Includes "with or without" load control switch for exerciser period.

Accessory 44A - Strip Heater with thermostat for extremely cold areas to prevent condensation and freezing of this condensation. External 120 volt power source required.

Accessory 44G - Strip Heater with thermostat, wired to load terminals: 208-240, 360-380, 460-480, 550-600 volts. Contains wiring harnesses for all transfer switch sizes.