Description
Features
- Briggs & Stratton Vanguard Engine - Premium-grade Vanguard engines are application engineered to power equipment that works for a living.
- Sure Flow Cooling System - The three cooling intakes provide exceptional air flow and reduced heat soak.
- DSE 3110 Digital Controller - Provides detailed operating and diagnostic information through its digital display.
- Prime Power Ready - This unit is appropriate for either Emergency Standby or Prime Power Applications like powering remote water pumps.
- Battery Charger - A Guest 3-Stage battery charger included
- 100% Load Tested - No statistical sampling here. Winco load tests every generator before it leaves their facility.
- Galvanealed Steel Weather Enclosure - Industrial galvanealed steel housing with powder-coat paint to withstand the elements.
PSS8 Generator Specifications
VOLTAGE REGULATION | +/-5% |
TOTAL HARMONIC DISTORTION | <5% |
TEMPERATURE RISE | 125°/40° C |
PHASE | SINGLE |
TYPE | 2 POLE ROTATING FIELD |
BRUSHLESS | YES |
GENERATOR SPEED | 3600 RPM |
VOLTAGE CONTROL | CAPACITOR |
ROTOR | 2/3 PITCH |
WINDINGS | 100% COPPER |
LOAD ACCEPTANCE | 100% RATING/SINGLE STEP |
SEALED BALL BEARINGS | 1 |
WAVE DISTORTION | <1.5% |
TELEPHONE INTERFERENCE | <2% |
INSULATION | CLASS H |
GENERATOR WARRANTY | 2 YEARS |
SHIPPING DIMENSIONS | 45" x 31" X32" |
SHIP WEIGHT | 400 LBS |
FREIGHT CLASS | 70 |
PSS8 Genset Specifications
MOTOR STARTING (CODE G) | 3 HP |
PRIME APPLICATIONS | YES |
STRUCTURAL CLEARANCE | 18" |
EPA APPROVED | YES |
CARB APPROVED | YES |
CSA APPROVED | YES |
UL2200 LISTED | YES |
OUTPUT 120/240 1PH LP GAS WATTS | 8,400 |
OUTPUT 120/240 1PH LP GAS KVA | 8.4 |
OUTPUT 120/240 1PH LP GAS AMPS | 35 |
OUTPUT 120/240 1PH NG GAS WATTS | 7,600 |
OUTPUT 120/240 1PH NG GAS KVA | 7.6 |
OUTPUT 120/240 1PH NG GAS WATTS | 32 |
CIRCUIT BREAKER AMPS | 35 |
WINCO WARRANTY | 1 YR/1000 HRS |
PSS8 Sound Data
NO LOAD | FULL LOAD |
LEFT | RIGHT | FRONT | BACK | LEFT | RIGHT | FRONT | BACK |
63.2 | 64.4 | 66.4 | 63.8 | 64.9 | 65.3 | 68.5 | 65.3 |
PSS8 2-Wire Control Features
FAIL TO START | YES |
FAIL TO STOP | YES |
LOW OIL PRESSURE | YES |
HIGH ENGINE OIL TEMP | YES |
UNDER FREQUENCY/SPEED | YES |
OVER FREQUENCY/SPEED | YES |
LOW VOLTAGE | YES |
HIGH VOLTAGE | YES |
BATTERY OVER/UNDER VOLTAGE | YES |
DIGITAL DISPLAY | YES |
PSS8 Engine Specifications
BRAND | BRIGGS & STRATTON |
MODEL | VANGUARD |
SPEED | 3600 RPM |
DISPLACEMENT | 570 CC/OHV |
CYLINDERS | V-TWIN |
LUBRICATION | FORCED W/SPIN-ON FILTER |
IGNITION | ELECTRIC |
GOVERNOR | MECHANICAL |
REGULATION | +/-1.8 HZ STEADY STATE |
EXHAUST | CRITICAL GRADE, GLASS-PACK |
LOW OIL PROTECTION | STANDARD |
HIGH OIL TEMP PROTECTION | STANDARD |
RECOMMENDED OIL | 10W-30 |
OIL CAPACITY | 1.5 QTS |
FUEL CONSUMPTION LP | 1.6 GAL/HR - 158,760 BTU/HR |
FUEL CONSUMPTION NG | 132 FT³/HR - 132,000 BTU/HR |
FUEL TANK SIZING 60°F (16° C) | 150 GAL |
FUEL TANK SIZING 32°F (0° C) | 150 GAL |
FUEL TANK SIZING 0°F (-18° C) | 250 GAL |
FUEL TANK SIZING -20°F (-29° C) | 500 GAL |
LINE SIZING UP TO 25' | 3/4" PIPE |
LINE SIZING UP TO 25' TO 100' | 1" PIPE |
LINE SIZING OVER 100' | USE A 2 REGULATOR SYSTEM |
INLET PRESSURE | 4-6 OZ / 7"-11" WATER COLUMN |
ENGINE WARRANTY | 3 YRS |
PSS8 Battery Specifications
DC SYSTEM VOLTAGE | 12V |
DC ALTERNATOR | ENGINE MOUNTED |
BATTERY RACK/CABLES | INCLUDED |
BATTERY CHARGER | 3 STAGE INCLUDED |
REQUIRED BATTERY(1) | GROUP 26 500 CCA |
Notes: (1) | Battery Not Included |
Printable Brochures:
Spec Sheet ASCO 185 Series Transfer Switch
Operating Manual Vanguard Engine Operating Manual
PSS8 Parts List Vanguard Engine Parts List